How to plot the efficiency – torque curve of a Permanent Magnet DC Motor?

If you’ve ever walked past a factory floor, seen a robotic arm maneuver a precision part, or even used a high-powered power tool that hums with consistent, reliable torque, chances are you’ve encountered a Permanent Magnet DC (PMDC) motor—one of the most workhorse motors in industrial and consumer applications. As a PMDC motor supplier, I get dozens of calls every month from engineers and operations managers asking a similar question: “How do I actually measure and plot the efficiency-torque curve for my motor?” It’s not just a trivial plotting exercise; this curve is the blueprint for choosing the right motor for your application, optimizing energy use, and avoiding costly downtime. Too often, teams skip the detailed testing and use generic curves from catalogs, leading to underpowered systems or wasted electricity. Today, I’m going to walk you through the step-by-step process we use in our facility to plot this curve accurately, straight from decades of refining our testing protocols for our own PMDC motors. Permanent Magnet DC Moto

First, let’s get on the same page about what the efficiency-torque curve actually is. A PMDC motor’s efficiency is the ratio of mechanical power output to electrical power input, multiplied by 100 to get a percentage. Torque is the rotational force the motor produces, measured in Newton-meters (Nm) or inch-pounds (in-lbs). The curve plots efficiency on the y-axis against torque on the x-axis, and it’s not a straight line—it has a distinct peak, usually at mid-range torque. Below that peak, efficiency drops because the motor is operating at very low load, where losses like friction and winding resistance dominate. Above the peak, efficiency also drops because copper losses (heat from current flowing through the motor’s windings) spike as torque increases. For us, this curve is non-negotiable for every custom and stock PMDC motor we ship; it’s how we ensure our products meet the exact needs of our clients, from small robotics manufacturers to large material handling companies.

Before you even touch a plotter or a spreadsheet, you need to gather the right tools and prepare your motor for testing. Skip the cheap, off-the-shelf multimeters that give rough readings—invest in calibrated equipment, because accuracy here will make or break your curve. First, a dynamometer: this is the device that applies a controlled load to the motor, measuring both the torque the motor produces and its rotational speed (RPM). For low-power PMDC motors (under 1 horsepower), a fan dynamometer works well, but for higher power, we use a eddy current dynamometer, which provides smooth, consistent load control. Next, you need a precision power analyzer to measure electrical input: voltage, current, and power factor (though for PMDC motors, power factor is close to 1, so it’s easy to work with). You’ll also need a tachometer to confirm RPM readings from the dynamometer—this cross-check eliminates errors from sensor drift.

Crucially, you need to prepare your PMDC motor for testing by running it in first. Break-in is non-negotiable for accurate results. Run the motor at no load for at least 30 minutes at its rated voltage to seat the bearings, burn off any residual lubricant fumes from manufacturing, and ensure consistent friction losses. For our motors, we do a 2-hour break-in period to account for any small initial variances in winding tension, which can skew torque and efficiency readings. If you skip break-in, your efficiency data will be all over the place, and your curve will be useless. We once had a client try to plot a curve on a new motor before break-in and got a peak efficiency 8% lower than it actually was—this led them to order a larger, more expensive motor that was overkill, costing them thousands in unnecessary equipment and energy costs. Don’t make that mistake.

Now, let’s walk through the testing process step by step. Start by setting up your test bench: mount the PMDC motor securely to a rigid frame, connect it to the dynamometer’s shaft, and ensure there’s no slack in the coupling (misalignment will cause extra friction and inaccurate torque readings). Connect the power analyzer to the motor’s input terminals, and sync the dynamometer and tachometer so they log data at the same interval—we use 10-second intervals, which gives us a balance of data density and test time.

First, run the no-load test. Set the dynamometer to apply zero load, so the motor spins freely. Apply the motor’s rated voltage, and let it stabilize for 5 minutes. Once stable, record four data points: input voltage (V), input current (I), no-load RPM, and no-load torque. No-load torque isn’t zero because even when spinning freely, the motor has to overcome bearing friction, air resistance, and core losses from the armature spinning through the magnetic field. For our mid-sized PMDC motors, no-load torque is usually around 5% of the rated full-load torque, so it’s a small value but critical for calculating later losses.

Next, incrementally increase the load on the dynamometer. We do this in steps equal to 10% of the motor’s rated torque, starting at 10% and going all the way to 120% of rated torque (to capture the efficiency curve beyond full load, which is useful for applications that occasionally need extra torque for short periods). For each load step, wait 3 minutes for the motor to stabilize—this gives time for winding temperatures to rise slightly (and reach a steady state, which minimizes error from temperature-dependent resistance) and for the dynamometer readings to settle. At each step, record the same four data points: voltage, current, RPM, and torque. We repeat this test three times for every motor to account for any small fluctuations in line voltage or dynamometer calibration, then average the readings to get our final dataset.

Now, the math part—this is where many teams get stuck, and where as a PMDC supplier, we’ve refined our formulas to avoid common mistakes. Remember, efficiency (η) is mechanical output power divided by electrical input power, times 100%. Mechanical power output for a motor is calculated as: (Torque (Nm) × Angular Velocity (rad/s)) / 1000, which simplifies to (Torque × RPM × 0.1047) / 1000 = Torque × RPM × 0.0001047 kilowatts (kW). Electrical input power is simply Voltage (V) × Current (I) in kW, because we’re working with DC, so power factor is 1. So the formula for efficiency is: η = [(Torque × RPM × 0.0001047) / (V × I)] × 100%. That’s it—no fancy constants, just straightforward DC power calculations.

Wait, let’s test that with an example from our latest 24V, 100W PMDC motor. At 50% rated torque (0.8 Nm) and 3500 RPM, torque × RPM × 0.0001047 is 0.8 × 3500 × 0.0001047 = 0.293 kW. If input power is 0.35 kW, efficiency is (0.293 / 0.35) × 100 = 83.7%—that’s right in line with our published curve for that motor. If you use inch-pounds instead of Nm, the formula is slightly different, but we always use SI units for consistency, so we don’t mix up conversions and mess up our curve.

Now, it’s time to plot the curve. We use Excel for most of our plotting, but for more precise curves, we use specialized motor testing software that fits a smooth line to the data points. First, make sure your x-axis is torque, ranging from 0 Nm to 120% of rated torque, and your y-axis is efficiency, ranging from 0% to 90% (since PMDC motor efficiency rarely exceeds 90% for most industrial models, though high-precision models can hit 92-95%). Plot each (torque, efficiency) pair from your test data. You’ll notice the curve starts at the origin (0 torque, low efficiency) because at no load, input power is all lost to friction and core losses, so mechanical output is zero. As torque increases, efficiency rises rapidly until it hits its peak—for our 100W motor, that peak is around 84% at 60% rated torque. Then, as torque goes above the peak, efficiency starts to drop, as copper losses from higher current outweigh the gain in mechanical power.

But here’s the key part for our customers: we don’t just plot the raw data. We also add a shaded area to the curve labeled “Safe Operating Range,” which is between 20% and 100% of rated torque. Running below 20% torque means the motor is operating at very low efficiency, wasting energy and leading to frequent on/off cycles if it’s driving a variable load, which shortens motor life. Running above 100% rated torque for extended periods will cause overheating and winding failure. We also add annotations for key points: peak efficiency, rated operating efficiency (at 100% torque), and no-load efficiency.

Now, let’s talk about common mistakes to avoid when plotting this curve, because these are the errors we see most often from teams that try to test on their own without proper guidance. First, not accounting for armature resistance changes with temperature. As the motor runs, the windings heat up, so their resistance increases, which changes current and power calculations. We run each load step until the motor reaches steady temperature—this usually takes 2-3 minutes per step. A client last year tried to rush their test, taking readings at 30-second intervals, and got a peak efficiency 5% lower than actual, because they were reading data while the motor was still warming up. Second, using line voltage without accounting for voltage drops in the power cables connecting to the motor. If your test bench is 20 feet from the power supply, a small voltage drop in the cables will make your input power calculation wrong. We measure the voltage directly at the motor’s terminals, not at the wall, to eliminate this error. Third, ignoring stray losses. At very high torque, there are small losses from eddy currents in the motor’s core that our formula doesn’t account for. For most applications, this is negligible, but for high-precision curves, we use a stray loss factor of 0.5% of input power for PMDC motors, which we’ve validated through years of testing.

As a PMDC motor supplier, this curve is at the heart of everything we do. When a client comes to us needing a motor for a conveyor belt that operates at 70% load 24/7, we pull up their application’s torque requirements and match it to our curve: if their required operating efficiency at 70% torque is 82%, we can recommend a motor that delivers exactly that, or if they need higher efficiency for lower energy bills, we can offer a higher-efficiency model with a peak efficiency of 86% that operates at 83% at their required load. We don’t just sell motors—we sell data, and the efficiency-torque curve is the most important data we provide.

Once you’ve plotted your curve, what do you do with it? For our clients, this curve becomes a reference point for motor sizing, energy auditing, and predictive maintenance. If a client’s curve starts to show a drop in peak efficiency over time, that’s a sign of worn bearings, contaminated windings, or misalignment, so we can help them schedule maintenance before the motor fails. For new applications, the curve lets them calculate annual energy costs: a motor with 80% efficiency at their operating load uses 25% more electricity than a motor with 85% efficiency, which adds up to thousands in savings over the motor’s 10-year lifespan.

I want to end with a word of advice from someone who’s been building and testing PMDC motors for over 15 years: don’t rely on generic catalog curves. Those are usually based on ideal test conditions, not real-world use. The curve you plot with your own motor, on your test bench, using your equipment, will be the most accurate picture of how your motor will perform in your application. If you’re in the market for a PMDC motor, or you need help testing and plotting your efficiency-torque curve, our team is here to walk you through every step. We’ve tested thousands of motors, refined our protocols to eliminate errors, and we can provide the data you need to make the right choice for your operation.

Permanent Magnet DC Moto Reference

  1. Bose, B. K. (2006). Power Electronics and Motor Drives: Advances and Trends. Elsevier.
  2. Chapman, S. J. (2019). Electric Machinery Fundamentals (5th ed.). McGraw-Hill.
  3. Underwriters Laboratories. (2021). Standard for Safety for Rotating Electrical Machines, Part 1: General Requirements. UL 1004-1.